Error messages
Compac dispensers and systems display error codes to alert users or technicians when something isn’t working as expected. Each code points to a specific issue — such as configuration errors, excessive flow, reverse flow, or problems with key components like the processor or K-Factor board. These codes are designed to speed up troubleshooting by clearly identifying the fault and often suggesting the required action (e.g. reconfiguring a setting, checking for leaks, or pressing a reset switch). If an error code appears, refer to the error message list to understand the cause and how to fix it. Quick action helps ensure the equipment runs safely and efficiently.
Error Code | Likely Cause | Suggested Action |
---|---|---|
Er 3 / Err 3 |
1. Price is not set in the Dispenser 2. Pump number is not set in the Dispenser |
1. If the dispenser is connected to a site Controller, the price on the dispenser should be set to 0.00 and the pricing should be sent from the Controller. If the dispenser is not connected to a site Controller, the price must be set on the dispenser. 2. Set the hose number in the dispenser. |
Er 8 / Err 8 | Excessive Reverse flow | Check that product is not flowing back into the tank once the delivery has finished. This can occur if the non-return valves on site are leaking. |
Er 9 / Err 9 | The Flow Meter is in an illegal error state |
Re-power the Dispenser. Check Meter cable for loose wires or bad connections. Replace the Meter or the Encoder board on the Meter. |
Err 91 | Meter sequence error | If 3rd Party Meter, check the wiring. |
Er 10 / Err 10 | Memory error Configuration data lost or corrupted |
Re-configure Dispenser. If problem persists, replace Memory / Processor Board. |
Er 12 / Err 12 | Display Error | Replace Display. |
Err 13 | Slave board has restarted | Power failure Hardware failure |
Err 14 | K Factor Board offline | Check the Bus connections and C5K Power Supply. |
Err 15 | K Factor board has restarted | Power failure Hardware failure |
Err 16 | K Factor board is not talking to the LCD Display | Check wiring Replace K Factor board or LCD Display |
Err 31 | Transaction has ended but fuel is still flowing | Solenoid leaking |
Er 41 / Err 41 | Pump not communicating with Controller |
1. If only one pump on the site is not communicating with the Controller, then the fault is likely to be in the pump: a. Check the comms wire connections on the comms board b. Check the Diagnostic LEDs on the Comms board in the Dispenser to diagnose cause c. Check the configuration and setup in the Dispenser 2. If all pumps on site are not communicating: a. Check the comms wire connections on the comms board b. Check comms cables between the Dispenser and the Controller c. Check setup and operation of the Controller |
Er 50 | Meter not communicating with Dispenser electronics | Check Meter connections. Check Dispenser configuration. Ensure the Meter ID in configuration matches the Meter hardware. |
Er 52 | Meter error | If the problem persists after repowering the unit, replace the meter. |
Er 53 | Meter stopped vibrating | Repower the unit. This may appear during startup and is normal. If it persists, replace the meter. |
Er 54 | Temperature sensor failure | Repower the unit. Replace the meter if the error continues. |
Er 55 | Meter not ready | Wait for the meter to calibrate. If the issue continues, repower the unit. |
Er 61 | Meter was not able to zero | This may be due to a leak or crystal build-up in the meter. Check for leaks/crystallization. Purge the line. If unresolved, remove the meter and pour hot water to dissolve crystals. If still not resolved, replace the meter. |
Er 62 | Meter could not reset batch | Try restarting the meter. Replace the meter if the problem persists. |
Er 71 | V50 meter is set but variant not selected | Configure device to either AdBlue / DEF or LPG. |
Abd | Display offline / Display Fault | Check all display connections and the slave board configuration. If necessary, check and replace the display. |
CNG 157 | Dispenser expected no flow | Potential Solenoid Valve leak. Repair or rekit solenoid. |
CNG 158 | Tank volume predictor uncertainty | Check for leaks in the dispenser’s hose or fittings. |
CNG 159 | Temperature Probe out of range | Re-calibrate Temperature Probe. |
CNG 160 | Pressure Probe alignment error | Re-calibrate Pressure Probes. |
CNG 161 | Temperature Compensation calculation is uncertain | |
CNG 162 | Generic CNG error with a number of potential causes | |
CNG 164 | Pressure Probe error | Check / replace / re-calibrate Pressure Probe. |
CNG 200 | Unauthorised flow | Gas is flowing without the Start switch having been pressed to start a fill. |
HOLD |
Two types of HOLD error: 1. “Soft” HOLD error that resets after the unit is re-powered 2. “Hard” HOLD error that does not reset after re-power May also show Error 14 |
Re-power the unit. If the HOLD error resets but persists, the SD card may be corrupt and need replacement. Refer to SD replacement procedure. If it does not reset, possible hardware fault in Power Supply PCB / Processor PCB / K-Factor PCB / other PCB or Bus cable. |
Calib c | K-Factor data integrity failure, or processor board replaced | Break the K-Factor switch seal and momentarily press the switch. |
Calib p | K-Factor board swapped/replaced | Break the K-Factor switch seal and momentarily press the switch. |
Calib | Unit needs calibration due to hardware change | Check K-Factor, temperature, and density calibration. |
Calib f | K-Factor is not set or is 00.0000 | Calibrate the unit and set the K-Factor. |
Air |
1. Air in the system 2. Density out of range 3. Coil amplitude too low while meter is operating (displayed until next sale) |
Ensure pump is running. Check tank and pipework for leaks. Purge system. Increase solenoid delay on K-Factor switch. |
Orun | Overrun – flow above preset | Check solenoid is closing. Increase the preset cutoff. |
5ump | Sump error – liquid detected in the sump |
Empty the sump. Check the dispenser for leaks. Check for water etc getting into the sump. |
Ga5 | LPG – Returned meter density too low | Calibrate meter density using the K-Factor switch. |
ABDL | Display LCD error |
Problem with K-Factor board talking to LCD. Check cables, plugs, etc. If issue persists, replace K-Factor board and/or LCD Display. |
Er FLO | Excess Flow | Maximum flow rate exceeded. Increase max flow rate setting or restrict flow. |
Er pr5t | Preset below MMQ | Enter a preset above or equal to the MMQ. |
ER DEN | Density or Temperature out of Range |
Calibrate meter density using K-Factor switch. Calibrate meter temperature using K-Factor switch. |